       We offer wide range of products 
        with most common grading available on each item. It includes Synthesis 
        grade, Extra pure grade, GR grade, ACS grade. Grading for special application 
        such as HPLC grade, Pesticide grade, Electronic grade, Biochemistry grade, 
        Histology and solvent for Trace Analysis etc.  
      The purity grade helps us to classify the large variety 
        of reagents that exist in the market. Purity grade is expressed in the 
        product name by means of a quality denomination that follows to the product 
        nomenclature (i.e. "Guaranteed Reagent" or "Extra
      Pure"). Several quality denominations are common to all manufacturers 
        but, in addition, every manufacturer creates its own quality denominations 
        for specific applications.  
      The purity levels and physical and chemical values indicated 
        for the products in this catalogue represent typical values. These percentages 
        and measures are not norms, nor are they specifications.  
      There is however a certain number of products for which 
        we have added a + sign to the quality indication, for example 97%+. For 
        these products the typical level of purity will be greater than the percentage 
        indicated next to the name of the substance.  
      In all other cases, the contents of a batch will be 
        close to the typical level of purity. And we supply Product Specification 
        sheets and Certificates of Analysis, as well as MSDS's (Material Safety 
        Data Sheets) with every order. 
      
        IL chemicals have large diversity in grading and types of use summarized 
        as follows:  
      Technical grade 
        These products are suitable for non-critical tasks in the laboratory such 
        as rinsing, dissolving or are used as raw materials in production tasks. 
       
      Synthesis reagents 
        Those reagents those are suitable for organic synthesis and preparative 
        applications.  
      Extra Pure grade 
        This quality is associated to products that are suitable for qualitative 
        and semi-quantitiative grades. These chemicals suitable for general laboratory 
        works, and in most cases, meet Most Pharmacopoeia (BP, USP etc.) Standards. 
       
      Pharmacopoeia Grade 
      Products and solutions meeting the purity requirements 
        of chemical products admitted in the pharmaceutical sector (pharmacopoeia 
        requirement such as NF, BP, USP, Ph Eur, DAB, DAC, JP, Ph Franc..) 
      For Analytical Purpose 
      This quality is suitable for most  analytical application,
      research and quality control.  
      Guaranteed Reagent
      (GR) 
        It is the ideal quality for laboratory purposes. Batch to batch reproducibility 
        is specially controlled to guarantee consistent analytical results. The 
        grade is equivalent to Analytical grade (A.R.) Reagent grade (R.G.),
      p.a. nomenclature of other manufacturers.  
      ACS reagent 
        Reagents meets the specification of American Chemical Society (ACS) Analytical 
        reagents found in most laboratories and are used in a wide variety of 
        analytical techniques for quality control, research and development.  
      HPLC reagent 
      Product range is specially made for high performance 
        liquid chromatography. Within this range there are different qualities 
        depending on whether they will be used for preparative chromatography 
        or analytical in isocratic or gradient mode. The range includes high purity 
        solvents, tested to meet strict UV absorbance specifications as well as 
        ion pair reagents. 
      Ion Pair Reagents 
 Ion pair chromatography is done when the analytes of 
        interest include ionic compounds that are difficult to separate by reverse 
        phase chromatography. Ion pair reagents are added to the movil phase and 
        combine with ionic analytes. The neutral compounds formed can be easily 
        chromatography by reverse phase HPLC. We offer both cationic and anionic ion pair reagents 
        in special HPLC grade qualities to assure trouble-free separations. 
      Pesticide & GC residue 
 Solvents are specially tested to avoid organic impurities 
        at ppt levels. These solvents are specially purified in a multi-step process 
        using only glassware equipment. Inert conditions are kept during bottling 
        to assure optimum performance and to avoid any possibility of contamination. 
      Dry & Anhydrous 
      Solvents with a very low water content, applicable for 
        analytical purposes or organic synthesis. Dry solvents are traditionally 
        used in water determinations according to Karl Fischer and anhydrous solvents 
        are becoming more necessary in the new organic and inorganic chemistry 
        research techniques. In our catalogue, you can also find extra-dry grade 
        solvent or extra-dry with molecular sieves. 
      Peptide and DNA synthesis 
 The most important features of these products are low 
        UV absorption and low water content. 
      Spectroscopy grade 
 Solvents display a high UV permeability and are subject 
        to strict IR Spectroscopy tests. 
      Food/ FCC grade 
        Products meet the strength specifications and maximum impurity limit indicated 
        in the Food Chemicals Codex (FCC)  
      Molecular biology reagents 
        These products are specially controlled to guarantee the absence of enzymes 
        that could interfere in the analysis and an adequate transparency for 
        the detection techniques used in molecular biology.  
      
        
        Biotech/ Biochemistry grade 
        Highly pure reagents suitable for biochemical research and analysis. The 
        critical parameters involved are absence of inhibitors such as traces 
        of heavy metals as well as biochemical function tests for enzymes, coenzymes 
        and enzyme substrates.  
      
        
        Microbiology grade 
        We offer hundreds microbiological products with some dehydrated culture 
        media auxiliary agent and other manual systems in its range.  
      
        
        Fluorescence grade 
        Our fluorescence HPLC grade is gradient and fluorescence controlled. It 
        is specially suitable for PAH analysis by HPLC  
      
        
        For Microscopy 
        IL offers various types of chemicals and reagents for microscopy use.  
      
        
        GPC reagent 
        Specially stabilized Tetrahydrofuran is available for GPC (gel permeation 
        chromatography). This THF can be used for column-storage, since it does 
        not form damaging peroxoides.  
      
        
        Cell Culture grade 
        IL cell culture reagents include cell culture media, laboratory preparations, 
        biological extracts, selective and sterile reagents for several applications.  
      
        
        Proteomics 
        Proteomics defined as the qualitative and quantitative comparison of proteomes 
        under different conditions to further unravel biological processes, we 
        offer reagents for these usage.  
      Histology grade 
        IL offers solvents and reagents purity meets the histological uses.  
      Ultra pure grade  
      IL Ultra pure reagents are used in inorganic trace analysis 
        where impurities must be low in the ppt or ppb level. Each reagent is 
        delivered complete with a lot analysis certificate. 
      Electronic/
      VLSI/ ULSI/ SLSI grade 
 Reagents used for semiconductor industry, cations, anions 
        and particles value guarantee to ppm to ppb level. Our range of chemicals 
        covers all products required in cleaning and etching processes for semiconductor 
        production. 
      ASTM products 
        In the analysis of oil derivatives it is of interest that the reagents 
        and apparatus are manufactured under the American Society of Testing and 
        Materials guidelines.  
      Acids with low mercury content 
        These acids are used in environmental analysis when analyzing traces of 
        mercury, and assure that no interferences are added to the samples because 
        of the acids.  
      AA and ICP standard solutions 1000ppm 
        They are made out of high-purity salts and acids, or bases. The accuracy 
        of its concentration is checked by using titrimetric and gravimetric methods. 
        These solutions can be used in atomic absorption spectroscopy, polarography 
        or colorimetric techniques. They are traceable to NIST with certificate 
       
      Volumetric solutions 
        Ready to use volumetric solutions and most of them are traceable to NIST. 
       
      pH buffer solution 
 IL offers a broad range of ready to use buffer solutions 
        for pH-meter calibration. They are accurate and traceable to NIST. Colored 
        solution of pH 4, 7, 10 available for easy differentiation. 
      Karl Fischer reagent 
 Karl Fischer titration is widely used to quantify water 
        content in many different samples. It is used both in industrial processes 
        and in quality control laboratories. Our KF reagents are pyridine-free, 
        which contain non toxic imidzole. It has a good buffer capacity and allows 
        fast and stable titration end-points 
      Abbreviations  
      
        AAS,  Atomic Absorption Spectrometry  
      ACS, American Chemical Society  
      APHA, American Public Health Association  
      ASTM, American Society for Testing and Materials  
      BP, British Pharmacopoeia  
      CAS, Chemical Abstracts Services  
      COD,  Chemical Oxygen Demand  
      CP, Chemical Pure  
      DAB, German Pharmacopoeia  
      DAC,  German Pharmacopoeia Codex  
      EP, Extra Pure  
      FCC, Food Chemicals Codex  
      FDA, Food and Drug Administration  
      GC, Gas chromatography  
      GE, Gel Electrophoresis  
      GMP, Good Manufacturing Practice  
      GR, Guaranteed Reagent, equivalent to Analytical
      Reagent of other suppliers  
      HDPE, High-density Polyethylene  
      HPLC,  High Performance Liquid Chromatography  
      IC, Ion Chromatography  
      ICP, Induction-coupled plasma  
      IR, Infrared spectroscopy  
      ISO, International Organization for Standardization 
       
      IUPAC, International Union of Pure and Applied Chemistry 
       
      JP, Japan Pharmacopoeia  
      LC, Liquid Chromatography  
      Mesh, British Standard Sieve  
      MS, Mass Spectrometry  
      NF, National Formulary  
      NIST,  National Institute of Standards and Technology 
       
      NMR, Nuclear Magnetic Resonance Spectrometry  
      PAH, Polycylic Aromatic Hydrocarbons  
      PCB, Polychlorinated biphenyls  
      Ph Eur, European Pharmacopoeia  
      Ph Franc, French Pharmacopoeia  
      TLC, Thin Layer Chromatography  
      USP, The United States Pharmacopoeia  
      UV, Ultraviolet Spectroscopy  
      VLSI, Very large-scale integrated circuits  
      
       
     |